Sheila, Haocun
We had lots of locklosses today, and some were probably caused by the side OSEM driving of the beamsplitter M1, as shown in the figures attached.
(H1:SUS-BS_M1_MASTER_OUT_SD_DQ & H1:SUS-BS_M1_DAMP_T_IN1_DQ)
It seems to have happened again at 22:20:12 UTC June 15th
Tagging SUS and CDS.
Tonight I had a look at several other of these locklosses, and other than the one at 23:57:59 that Hoacun plotted, it seems mostly like the glitch in the side osem comes after the lockloss. Many of these locklosses seem to happen durring the CM board switching.
It does seem like it would be worth investigating this side osem issue, since we know that it causes at least some locklosses.