Violin Mode damping work (cont.)

Stefan, Nutsinee

A very quick summary: ITMY modes rung up tonight. All the damp settings has been changed. I suspect ETMX damp phase might have been changed as well. ITMX didn't seen to have a problem. We suspect the ring heater changed the violin mode frequency.

 

Below I attached a screenshot of what works on ITMY modes tonight.

Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 14:04, Wednesday 15 June 2016 (27754)

We looked at the frequency of mode 8 last night, two nights before around GW151226 and after a O1 power ouitage (20151025 9UTC). (attached)

Two days ago the mode was heavily damped, so the frequency estimate might be a bit off. At any rate, all frequencies are within 3mHz (or 22deg of feed-back phase in the current band-pass filter). So we ough to be able to damp this mode consistently.