Displaying report 1-1 of 1.
Reports until 13:05, Thursday 16 June 2016
H1 IOO (IOO, SUS)
cheryl.vorvick@LIGO.ORG - posted 13:05, Thursday 16 June 2016 (27773)
noise on IM2 OSEM LR vs noise (or lack of) on IM1 OSEM LR

IM2 shows more motion in pitch and yaw than IM1, IM3, or IM4. Below is a chart showing the p-p amplitude of the oscillations in the damping signals, in urad, for pitch and yaw.

  DAMP_P_IN (urad) DAMP_Y_IN (urad)
IM1 0.5 0.5
IM2 3.0 2.5
IM3 0.7 0.6
IM4 1.0 0.5

Attached is a power spectrum taken today showing OSEM LR, DAMP L, and COIL OUT LR for IM1 and IM2.

See also: alog #26502, alog #25955, alog #25811

Images attached to this report
Displaying report 1-1 of 1.