Displaying report 1-1 of 1.
Reports until 13:11, Thursday 16 June 2016
H1 CDS
patrick.thomas@LIGO.ORG - posted 13:11, Thursday 16 June 2016 - last comment - 13:26, Thursday 16 June 2016(27775)
Updated Conlog channel list
Added 184 channels. Removed 8 channels. (see attached)
Non-image files attached to this report
Comments related to this report
david.barker@LIGO.ORG - 13:26, Thursday 16 June 2016 (27776)

I remembered that generating the Guardian autoBurt.req file is very hands-on at the moment and was very much out of date (from early O1)

I re-created the autoBurt.req, which allowed conlog to stop attempting to connect to the removed node and now connects to the new nodes. For the record, we now have 97 Guardian nodes running.

Procedure to update /opt/rtcds/lho/h1/target/h1guardian0/h1guardian0epics/autoBurt.req file:

edit the create_guardian_autoburt.py script to get the node listing correct (I use 'guardctrl list')

save the current autoBurt.req into the archive directory

./create_guardian_autoburt.py > autoBurt.req

Then test with

burtrb -f autoBurt.req

Displaying report 1-1 of 1.