Reports until 09:45, Friday 17 June 2016
LHO VE
chandra.romel@LIGO.ORG - posted 09:45, Friday 17 June 2016 - last comment - 22:08, Friday 17 June 2016(27806)
CP5
Raised CP5 Dewar pressure (3/4 turn at pressure regulator + 1/4 turn yesterday). Will take days to read a pressure response. Current pressure is 17.5 psi in tank and 15 psi at exhaust. 

Also filled CP5 to 100% with 1/2 turn open on LLCV bypass valve. 
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:09, Friday 17 June 2016 (27817)

CP5 "setting % open" has been shifting upward.  The vacuum team is working to try to get it under control.  Last week such setting was around 88% now is oscillating around 100%.

Note to operators if "cryopump level % Full" falls below 88% it will be very hard for the current system to bring it up to nominal (92%), if it does reach that point, feel free to call a member of the vacuum team, the cryopump will need manual filling.

Images attached to this comment
chandra.romel@LIGO.ORG - 17:13, Friday 17 June 2016 (27818)
Trend data.
Images attached to this comment
kyle.ryan@LIGO.ORG - 22:08, Friday 17 June 2016 (27824)
I am also monitoring from home - I don't think that there are "operators" working the weekends(?)