stefan.ballmer@LIGO.ORG - posted 13:36, Wednesday 22 June 2016 (27916)
SRC1 loops closed at 37W

The guardian is currently set up to go to 40W requested (actualkly 37W).. With the interferometer sitting at this power level for ~1h I picked a possible SRC input matrix: Both A36I and B36I have signal, but different offsets. The combination below brings us to a good sideband buildup:

for SRC1_P:
AS_A_RF36_I : -0.5
AS_B_RF36_I : +1.0

for SRC1_Y:
AS_A_RF36_I : -1.5
AS_B_RF36_I : +0.34

Attached are snapshots of the input matrices at 37W

 

Images attached to this report