corey.gray@LIGO.ORG - posted 20:26, Wednesday 22 June 2016 (27930)
DRMI Lockloss: Arm Dark Offset Guardian Bug?

While locking this evening, Sheila noticed that while H1 was locked in DRMI & after it went through PREP_TR_CARM, the Arm Offsets were put at wrong values (which would have prevented us from FINDING IR for later locks).  

In Guardian, we basically take an average of 1sec of data of the IN1 signals & then this avg is entered as the offset (with a "-" sign).

[From the ISC_LOCK.py script]      

This sounds like it makes sense, but for our lockloss, Guardian took BOTH offsets to 0.0  (and the IN1 signals were clearly not 0.0).  So this looks rather dubious.  Attached is 6-seconds of data for both X&Y arms.