Attempted to bring the interferometer back to 40W in an attempt to leave it at 40W over night.
- Slightly tweaked the yaw offsets of the QPDs to improve the PR gain, but ran out of patiance at a recycling gain of 28 - I think there is more to be had with better alignment..
(The offsets I used were in the control filter modules: H1:ASC-DSOFT_Y_OFFSET=0.08, H1:ASC-CSOFT_Y_OFFSET=0.04)
- Then the OMC DCPDs started saturating - for now I just turned off the PD whitening.
- Added the input matrix from alog to Guardian - but Guardian still does not turn the SRC1 loop on when it gets there.:
for SRC1_P:
AS_A_RF36_I : -0.5
AS_B_RF36_I : +1.0
for SRC1_Y:
AS_A_RF36_I : -1.5
AS_B_RF36_I : +0.34
However, the soft loops ran away several times during powerup - not sure what changed.