Displaying report 1-1 of 1.
Reports until 11:04, Monday 27 June 2016
H1 CAL
jeffrey.kissel@LIGO.ORG - posted 11:04, Monday 27 June 2016 (27978)
PCALY Calibration Lines Found OFF; Turned back ON
J. Kissel,

Not sure why (couldn't find a aLOG), but the SDF system found that the PCALY calibration lines at 36.7, 331.9, and 1083.7 have been off since Monday Jun 20. I've turned them back on, such that we can get as much information about this week's lock stretches as we can. This was done by setting the SIN and COS amplitudes back to 125, 2900, and 15000 [ct] respectively.
Images attached to this report
Displaying report 1-1 of 1.