Displaying report 1-1 of 1.
Reports until 10:54, Tuesday 28 June 2016
H1 CDS
james.batch@LIGO.ORG - posted 10:54, Tuesday 28 June 2016 (28007)
Replacement of 18bit DAC successful for h1susb123, h1sush2a
WP 5954

All of the 18bit DAC cards in h1susb123 and h1sush2a now successfully pass the autocal on both power up and restart of the IOP models.  Results shown below:

h1susb123 - power up
[   61.694760] h1iopsusb123: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   67.057232] h1iopsusb123: DAC AUTOCAL SUCCESS in 5340 milliseconds
[   72.850938] h1iopsusb123: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   78.213461] h1iopsusb123: DAC AUTOCAL SUCCESS in 5345 milliseconds
[   85.247010] h1iopsusb123: DAC AUTOCAL SUCCESS in 6571 milliseconds
[   90.610149] h1iopsusb123: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   95.973497] h1iopsusb123: DAC AUTOCAL SUCCESS in 5345 milliseconds
[  101.336018] h1iopsusb123: DAC AUTOCAL SUCCESS in 5340 milliseconds
h1susb123 - IOP model restart
[  911.921930] h1iopsusb123: DAC AUTOCAL SUCCESS in 5344 milliseconds
[  917.282286] h1iopsusb123: DAC AUTOCAL SUCCESS in 5345 milliseconds
[  923.070351] h1iopsusb123: DAC AUTOCAL SUCCESS in 5341 milliseconds
[  928.430617] h1iopsusb123: DAC AUTOCAL SUCCESS in 5344 milliseconds
[  935.453979] h1iopsusb123: DAC AUTOCAL SUCCESS in 6576 milliseconds
[  940.814416] h1iopsusb123: DAC AUTOCAL SUCCESS in 5345 milliseconds
[  946.174750] h1iopsusb123: DAC AUTOCAL SUCCESS in 5345 milliseconds
[  951.535191] h1iopsusb123: DAC AUTOCAL SUCCESS in 5341 milliseconds

h1sush2a - power up
[   48.086815] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   53.450158] h1iopsush2a: DAC AUTOCAL SUCCESS in 5345 milliseconds
[   60.479701] h1iopsush2a: DAC AUTOCAL SUCCESS in 6576 milliseconds
[   65.843077] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   71.640028] h1iopsush2a: DAC AUTOCAL SUCCESS in 5345 milliseconds
[   77.001396] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[   82.364713] h1iopsush2a: DAC AUTOCAL SUCCESS in 5345 milliseconds
h1sush2a - IOP model restart
[ 1252.909059] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[ 1258.269410] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[ 1265.292831] h1iopsush2a: DAC AUTOCAL SUCCESS in 6572 milliseconds
[ 1270.653176] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[ 1276.441059] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[ 1281.801414] h1iopsush2a: DAC AUTOCAL SUCCESS in 5344 milliseconds
[ 1287.161817] h1iopsush2a: DAC AUTOCAL SUCCESS in 5345 milliseconds
Displaying report 1-1 of 1.