Displaying report 1-1 of 1.
Reports until 15:26, Tuesday 28 June 2016
LHO VE
chandra.romel@LIGO.ORG - posted 15:26, Tuesday 28 June 2016 (28021)
threadlocker on CP LLCV stems
Surveyed all eight CP LLCV stems for loctite blue 242 application. CPs 2, 4, 5 now have loctite and were re-zeroed (CP5 has broader range). The others' stems were so tight that I couldn't loosen, so I assumed they don't need loctite.

NOTE:  CP 2 & 5 stems were starting to unthread from the actuator coupling nut again, prior to loctite application. 



Displaying report 1-1 of 1.