Reports until 11:42, Wednesday 29 June 2016
H1 DetChar (DetChar, ISC)
gabriele.vajente@LIGO.ORG - posted 11:42, Wednesday 29 June 2016 - last comment - 11:45, Wednesday 29 June 2016(28054)
Brute force coherence

Lisa asked me to run a BruCo scan on data from this elog entry: 27990 (June 28, 6:00 - 6:10 UTC)

The report is available at the following address:

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1151128817/

Instead of CAl_DELTAL I used directly the OMC_DCPD_SUM signal. The reason is that the usual calibration of CAL_DELTAL does not seem to be correct anymore.

In summary:

For future reference, to run BruCo you can follow this procedure

  1. log in into one of LDAS machines, for example ldas-pcdev1.ligo-wa.caltech.edu
  2. download the bruco code from the git repository https://github.com/gabrielevajente/bruco
  3. read the first lines of the bruco.py script for instructions. To produce the report above I used the following command:
    ./bruco.py --ifo=H1 --channel=OMC-DCPD_SUM_OUT_DQ --gpsb=1151128817 --length=600 --outfs=4096 --naver=300 --dir=~/bruco_1151128817 --top=100 --webtop=20 --xlim=1:1000 --ylim=1e-10:1
Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 11:45, Wednesday 29 June 2016 (28056)

Thank you, Gabriele.