8 minutes of power up - alignment changes

biggest = prm pitch changing by 2.5urad

close second = im4 pitch changing by 1,15urad

plot and chart of top 16 optics/DOFs attached

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 13:03, Thursday 30 June 2016 (28089)

plot of optics/DOFs in the chart - meant to attach yesterday.  I

used OpLev signals when available and OSEMs when not.

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 10:13, Friday 01 July 2016 (28116)

UPDATE to my alog's less than descriptive title:  I think the original title suggests these changes were during a 40W lock, but this is not the case.  

The optic alignment changes are actually happening over 8 minutes of full lock while the input power increased from 22W, the O1 power level, to 40W.