New filters for CHARD Yaw low bandwidth

Sheila, Haocun

We designed some new filters for the low bandwith CHARD Yaw at 40W.

We plan to lower the gain for about 6dB, which will give us a UGF at 3.5Hz and use the new filters 6 ('40W') and 7 ('ctrlHBW') to stablize the loop (blue curve in the 2nd Figure). The new cutoff filter for 40W is filter 9 ('cutoff40W') (Figure 1). The pink curve in the second curve is what we expect from the simulation.