jeffrey.kissel@LIGO.ORG - posted 19:08, Wednesday 29 June 2016 (28070)
Added AOM Diffracted Power and Decreased Step Size Increments on PSL ISS 2ND Loop Screen
J. Kissel

Several lock losses were caused by DC coupled ISS loops today, so in my desperation to make things better, I modified the PSL ISS 2ND Loop MEDM screen to include all the relevant PSL AOM Diffracted Power information on the same screen (formerly only available on the 1st loop ISS screen). Also, to facilitate the turn on dance, I've decreased the default increment on the slider used to tune the analog reference signal (H1:PSL-ISS_SECONDLOOP_REF_SIGNAL_ANA) and increased the precision which the reference signal value is displayed.

The updated screen has been committed to the user apps repo here:
/opt/rtcds/userapps/release/psl/common/medm/ISS/PSL_CUST_SECONDLOOP.adl
Images attached to this report