C. Cahillane
After taking a close look at the Hanford actuation measurements, with the addition of the January 7th measurements, it became very obvious that the actuation measurements were never compensated for time dependence.
I am not sure if the same is true at Livingston. I will be investigating shortly. If so, it could be a major reason why LLO actuation uncertainty is so large... Previously, I used only calibration-week actuation measurements for LHO, meaning the kappas could not have varied too crazily in that period. But LLO had measurements more spread throughout the run.
This is obviously quite important for our uncertainty budget... The systematic errors will be affected on the order of the kappas that were never applied, so about 3% for TST and 2% for PUM and UIM. The uncertainties will be smaller since removing time-dependence will cluster our measurements better.
I have posted a plot similar to the one from aLOG 27290 showing the actuation magnitude variances and covariances between each day's measurements.
Blue is the measurements without the kappas applied. Red is with the kappas applied.
Comparing to aLOG 27290, we see UIM and PUM variances stay about the same, which makes sense because kappa_pu is not that volatile.
But TST variance goes from 2.5% to 2.0%!
I have added the following scripts to the calibration repository:
analyze_pcal_20150928_kappa_corr
H1PCALparams_20150826_kappa_corr
H1PCALparams_20150828_kappa_corr
H1PCALparams_20150829_kappa_corr
H1PCALparams_20160107_kappa_corr
These allow me to correct the LHO time dependence in our actuation functions.