Displaying report 1-1 of 1.
Reports until 10:15, Thursday 10 May 2012
H2 ISC
jameson.rollins@LIGO.ORG - posted 10:15, Thursday 10 May 2012 (2811)
RFM communication established between h2iscey and h2sustmsy and h2susetmy

The following RFM senders (library part cdsIPCx_RFM) are now in h2iscey:

H2:ISCEY-SUSTMSY_PIT
H2:ISCEY-SUSTMSY_YAW
H2:ISCEY-SUSETMY_LONG
H2:ISCEY-SUSETMY_PIT
H2:ISCEY-SUSETMY_YAW

I have also added the corresponding receivers to h2sustmsy and h2susetmy.

All models have been recompiled, installed, and restarted.  I have tested the connections, by applying offsets to the filter modules that output to the senders, and the connections seem to be working fine.

I have left the outputs and inputs to the filter modules that connect to the RFM senders and receivers off for now.  The input to the H2:ISCEY-SUSETMY_LONG sender is just a constant at the moment (value = 666), since there is no control signal for that output yet.  That will likely be added today.

I note, since I forgot, the receivers need to have their inputs grounded to indicate they are receivers. Otherwise the model will fail to compile.  Similarly, you can not ground the input on a sender or it will be interpreted by the RCG as a sender.  If the input to the receiver needs to be set to a specific value the Simulink "constant" part can be used.