IO IM1-4 alignment changes as IMC oscillates from 25W to 57W

I looked at 1 hour of the input power / IMC power oscillations that occurred last weekend and how that power change effected the alignment of the IO IMs, IM1, IM2, IM3, and IM4.

4 attachments: 

One explanation for the difference of IM2 compared to IM1, IM3, and IM4, is that the beam on IM2 is no longer centered, so the change in IMC power causes the optic to change alignment.

If this is true, the change of the beam centering on IM2 could be big enough to have significantly changed the alignment of the beam through the Input FI.

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 15:57, Friday 01 July 2016 (28125)

UPDATE: IM1 glitching

IM1 UR OSEM signal is glitching and the glitches can be seen in DAMP_P and DAMP_Y at about 0.1urad in both signals. 

These glitches do not show up in IM4 Trans.

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 16:21, Friday 01 July 2016 (28127)

UPDATE: IM2 oscillations clearly seen on IM4 Trans:

  amplitude (p-p)
IM4 trans pitch 0.035
IM2 pitch 0.25urad
IM4 trans yaw 0.015
IM2 yaw 0.25urad

Plot attached shows IM4 trans pitch and IM2 damp_p in blue, IM4 trans yaw and IM2 damp_y in green.

Images attached to this comment