Reports until 13:17, Tuesday 05 July 2016
H1 CAL (SUS)
jeffrey.kissel@LIGO.ORG - posted 13:17, Tuesday 05 July 2016 (28156)
New (and Old) SUS Oscillator Excitation Signals Added to Frames
J. Kissel, D. Barker

As Darkhan caught last week (LHO aLOG 28126), when we installed the new individual stage oscillators on the QUADs (LHO aLOG 27733), we neglected to store the excitation channels in the frames. Today, I've added those channels to the ETM QUAD master model, stored inthe science frames at 512 Hz, and restarted the SUS. 

Channels:
H1:SUS-ETMY_LKIN_P_LO_DQ           512
H1:SUS-ETMX_L1_CAL_LINE_OUT_DQ     512
H1:SUS-ETMX_L2_CAL_LINE_OUT_DQ     512
H1:SUS-ETMX_L3_CAL_LINE_OUT_DQ     512
H1:SUS-ETMX_LKIN_P_LO_DQ           512
H1:SUS-ETMY_L1_CAL_LINE_OUT_DQ     512
H1:SUS-ETMY_L2_CAL_LINE_OUT_DQ     512
H1:SUS-ETMY_L3_CAL_LINE_OUT_DQ     512

Model Change to:
/opt/rtcds/userapps/release/sus/common/models/QUAD_MASTER.mdl