Reports until 15:39, Thursday 10 May 2012
H2 SUS
sebastien.biscans@LIGO.ORG - posted 15:39, Thursday 10 May 2012 (2817)
SUS Procedure
Hi,

Find attached a very first version of the SUS generic scripts procedure.
All my scripts are working right now at LHO. I am looking forward to trying them at LLO.

So far,

Positive points: 

- Everything is generic. The user just needs to run a function in Matlab, providing some informations (IFO, Optics, ...). The results will be display in the command window.
- Everything is very easy to use, even for somebody who is not familiar with Matlab
- Allow to do all the first steps in two hours, and to run a full set of transfer functions during a night. Thus, the testing of a suspension can be done in a day if everything goes well.

Negative points:

- So far, nothing is really saved (except for the transfer functions), but just plotted. 
- All the scripts are in the same folder (SusVN/sus/trunk/Common/Generic_Testing_Scripts/). For now it is a bit of a mess.


I am looking forward to talking with Jeff Kissel to see what we really need to save, and how we can organize the folders.

Cheers,
Sebastien
Non-image files attached to this report