H1 Update: work on laser is done, locking full IFO resumes

Peter was in the PSL enclosure and looking at the FSS - his alog will give details.

He's done so I'm starting to lock.

Comments related to this report
cheryl.vorvick@LIGO.ORG - 09:36, Thursday 07 July 2016 (28223)

DRMI locked at 16:36UTC

cheryl.vorvick@LIGO.ORG - 09:46, Thursday 07 July 2016 (28225)

POP X PZT railed, but POP signal is still centered on the QPD, so this is on the "to be fixed" list, but does not prevent locking. POP X is accessable from the ASC overview screen.

cheryl.vorvick@LIGO.ORG - 10:18, Thursday 07 July 2016 (28227)

in DC READOUT TRANSITION, OMC guardian was stuck in DOWN, and was unstuck by running it through INIT.

cheryl.vorvick@LIGO.ORG - 10:35, Thursday 07 July 2016 (28228)

I unintentionally killed the lock by requesting the INCREASE POWER state in ISC_LOCK.  

I thought this would just stop the ISC_LOCK guardian in this state, keeping the input power at 38W.

Instead it reran the code for INCREASE POWER from the beginning and lowered the input power to 10W, killing the lock.

cheryl.vorvick@LIGO.ORG - 10:52, Thursday 07 July 2016 (28230)

Broken:

So I thought the power was going to increase to 50W, based on what the LASER_POWER guardian main screen was showing, however TJ explained that the guardian can only request so many states, so the power was going to stop at 40W but the guardian could not show that because 40W was not a requestable state.

Fixed:

TJ rewrote the LASER_POWER guardian to make 40W a requestable state, so when we're going to 40W it will show this.

TJ also set the ISC_LOCK to stop at 25W input power on out next lock.

cheryl.vorvick@LIGO.ORG - 11:07, Thursday 07 July 2016 (28231)

Currently, we have the IMC locked and at 40W input power.

Keita is looking at the ISS Second Loop and measuring the correct offset for 40W.

cheryl.vorvick@LIGO.ORG - 11:32, Thursday 07 July 2016 (28234)

18:32UTC - adjustments made for running at 25W are complete - now relocking H1

cheryl.vorvick@LIGO.ORG - 11:43, Thursday 07 July 2016 (28235)

DRMI locked at 18:43UTC

cheryl.vorvick@LIGO.ORG - 12:13, Thursday 07 July 2016 (28238)

19:12UTC - H1 in DC readout and heading to ENGAGE ISS 2nd loop

cheryl.vorvick@LIGO.ORG - 12:59, Thursday 07 July 2016 (28239)

19:58UTC -------------

H1 made it to ENGAGE ISS 2ND LOOP which is good, because getting to the point where we could engage the 2nd loop is progress, however engaging the loop revealed an issue which broke the lock.  

Jenne and Keita are looking into it.

******** my estimate of having H1 in Observer was a bit optomistic - 4PM today (23:00UTC) is more likely.

cheryl.vorvick@LIGO.ORG - 14:06, Thursday 07 July 2016 (28240)

21:04UTC - locked and going to ENGAGE_ISS2ND_LOOP without engaging the loop, to do measurements

cheryl.vorvick@LIGO.ORG - 14:13, Thursday 07 July 2016 (28241)

lockloss

cheryl.vorvick@LIGO.ORG - 14:53, Thursday 07 July 2016 (28244)

last entry for this log:

21:52UTC - H1 is back in ENGAGE ISS 2ND LOOP with the ISS 2nd loop disabled.

Keita and Jenne are looking for a fix, so H1 can go to Observe.