Displaying report 1-1 of 1.
Reports until 22:59, Saturday 09 July 2016
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 22:59, Saturday 09 July 2016 - last comment - 02:54, Sunday 10 July 2016(28310)
Finally locked at NLN

Intent bit set at 05:30 UTC. PI modes are not well damped but they're controlled for now. There are few weird things I noticed about some of the PI modes:

 

 

As I was writing this alog, the ifo went DOWN because of ETM bounce mode (not sure which ETM, possibly both). I didn't put them on my StripTool since I was assume only ITMX has problem. Huge mistake...

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 00:26, Sunday 10 July 2016 (28311)

Locked again at NLN. Intent bit switched to Undisturbed at 07:22 UTC. I'm going to stick around a bit to keep an eye for the bounce mode and PI. PI modes are somewhat under control. Bounce and Roll modes seem pretty well damped at this point.

 

Hence a beautful ending of ER9.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 02:54, Sunday 10 July 2016 (28312)
The IFO lost lock and relocked itself after I came home so the intent bit is no longer set. It would be nice to have a way to set the intent bit remotely.
Displaying report 1-1 of 1.