Displaying report 1-1 of 1.
Reports until 12:01, Friday 03 June 2016
H1 INJ (INJ)
evan.goetz@LIGO.ORG - posted 12:01, Friday 03 June 2016 - last comment - 19:06, Thursday 14 July 2016(27543)
Amplitude of CW injections changed on restart -- why?

The CW injection amptlitude, as measured at the HARDWARE_OUT, appears to have changed on restart May 12. So far, I have not been able to trace down the problem, and conlog is currently down so I cannot see a history of chagnes in the HARDWARE_OUT bank.

Figure 1 observations (10 minute trend of HARDWARE_OUT):

Figure 2 observations (10 minute trend of CW_OUT):

Need conlog to investigate further.

Images attached to this report
Comments related to this report
evan.goetz@LIGO.ORG - 19:04, Thursday 14 July 2016 (28423)

On Jan 20, there was a site-wide power outage (alog 25041), and after everything was restored, one of the filter modules (FM3) was not turned on, but it should have been. This was the 1/AI2 filter with design:

zpk([1.2627e3 - i*2.6133e3;1.2627e3 + i*2.6133e3],[7000;7000],1,"n")

Turning this off flips the phase of the injected signal, but it doesn't really explain the drop in the signal amplitude that I would have expected.

One thing interesting is that there was considerable high frequency noise on the PINJX_HARDWARE_OUT time series that is reduced by turning off the 1/AI2. I plotted the spectrum of the HARDWARE_OUT channel before and after, separated by 24 hours so that the pulsar injections are approximately the same amplitude. Sure enough, with the 1/AI2 filter on, there is a large peak at 7 kHz with an amplitude nearly as large as the highest frequency pulsars. Is this why the pre-power outage time series is about twice as large? It is certainly suspicious...

evan.goetz@LIGO.ORG - 19:06, Thursday 14 July 2016 (28424)

See attached figures for pre- and post-power-outage spectrum.

Images attached to this comment