Weigang Liu tried folding DARM and selected magnetometer channels during the three days of ER9 (UTC days) with results posted here: https://ldas-jobs.ligo.caltech.edu/~weigang.liu/advancedLIGO_3/ER9/files/ER9_magnetometers_and_strain_list.html, where DARM folding focused on the 10-50 Hz band, and the magnetometer folding was low-pass below 50 Hz, choices motivated by O1 experience. As expected, the magnetometer channels still exhibit a variety of pathologies with 2-second periodicity, but the elevated low-frequency noise in DARM make it hard to see this 2-second contamination in that channel with this method. Attached are a few sample magnetometer fold summaries over the three days.