Displaying report 1-1 of 1.
Reports until 14:21, Thursday 14 July 2016
H1 ISC
stefan.ballmer@LIGO.ORG - posted 14:21, Thursday 14 July 2016 - last comment - 14:03, Friday 15 July 2016(28411)
Commissioning goals

*track AAA: PSL
- fix FSS re-locking problem

*track A: missing RG gain:
- PR2 spot position during alignment
- Add digital camera of BS
- arm optics camera defocus & power monitor
- *** fix the 2x omega diodes for SB recycling gain readout
   - check broadband mod of 2w PDs (POB and AS)
   - new lens in front of POB_B

*track B: noise commissioning?
 - shot noise scaling?
  - check calibration
  - try for 50W stable. Serious trouble with PI?
  - pick operating point, then now-noise commissioning
  - reduce RF45
  - Aux length show exess noise - fix it!

Comments related to this report
peter.fritschel@LIGO.ORG - 14:03, Friday 15 July 2016 (28437)

Relevant to noise hunting: all test mass PUM coil drivers should be put in a lower noise state than state 2 (which is the noisiest state). State 4 is the lowest noise, but state 1 should be adequate as well. See 28264.

Displaying report 1-1 of 1.