Shift Summary - Day
TITLE: 07/18 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Jeff
SHIFT SUMMARY:
  • 1st locking attempt failed after DC Readout acheived. Reason not known
  • 2nd attempt made it to COIL_DRIVERS and the Guardian code crashed.
  • IFO held in DOWN state for SDF clearing work  
  • Richard requests Activation of Fast Shutter at DC readout/2W
  • FSS and IMC being super-finicky this morning
  • Carl Blair did dome 'ramping' testing on the ITMs
  • IFO Locked at DC-READOUT_TRANSITION for most of the afternoon for commissioning work
LOG:
17:02 John down to MY

17:14 John back

18:00 back to locking after SDF party

19:43 Tested Fast Shutter function. Fil witnessed the proper operation.

22:55 Hand off to Jeff

 

 