Displaying report 1-1 of 1.
Reports until 13:22, Tuesday 19 July 2016
H1 PSL
peter.king@LIGO.ORG - posted 13:22, Tuesday 19 July 2016 - last comment - 15:42, Tuesday 19 July 2016(28496)
ISS RF
Measured the 80 MHz RF level at the output of the balun in the distribution panel in
the PSL rack.  This provides the local oscillator for the ISS AOM driver.  Originally
a 5 dB attenuator was at the output of the balun.  All RF powers were measured with
the Agilent RF power meter.

+13.0 dBm at the balun

+8.2 dBm at end of cable to the AOM driver with a 3 dB attenuator installed
+10.2 dBm at end of cable to the AOM driver with a 1 dB attenuator installed

    Left the 1 dB attenuator in place as this yields the right RF level for the AOM
driver input.

    Anecdotally it seems to me that the RF level has been dropping over the past few
months.
Comments related to this report
peter.king@LIGO.ORG - 15:42, Tuesday 19 July 2016 (28501)
AOM driver RF output power versus modulation input voltage.
Images attached to this comment