Data dropouts in second trend data

The data dropouts observed in second trend data (see alog 28579) are a result of missing data caused by restarts of frame writer 1.  If the raw data is used instead of second trend data, you can see that dropouts are not present, see attached example.  Both nds0 and nds1 are reading the same second trend data, and only frame writer 1 is currently writing second trend data as we explore frame writer instability.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:43, Friday 22 July 2016 (28584)

fw0 continues to be 100% stable, fw1 is now restarting about 12 times a day.