hugh.radkins@LIGO.ORG - posted 10:55, Tuesday 15 May 2012 (2862)
H2 BSC6 ETMY HEPI Channels appear backwards
We confirmed physically the readbacks of the position sensors were in the correct arrangement but the corner2 & corner4 Actuator drives are reversed. Vincent will look through the model to find the issue.
Jim, Vincent, Hugh