Reports until 20:26, Monday 25 July 2016
H1 ISC
evan.hall@LIGO.ORG - posted 20:26, Monday 25 July 2016 - last comment - 19:07, Tuesday 26 July 2016(28630)
ASAIR B PD swap

Koji, Evan

We removed the unmodified BBPD S1200242 from ISCT6, and replaced it with S1200236, which has the modifications described in G1500595.

Comments related to this report
koji.arai@LIGO.ORG - 19:07, Tuesday 26 July 2016 (28663)

Evan already compensated 12dB (x4). This is indeed consistent with the transimpedance difference betwen the old (1800Ohm@90MHz) and new (450Ohm) BBPD. 

The attached plot shows the difference of the normalized RF90 before and after the swap. The gain is matched within 3%.

Images attached to this comment