Reports until 11:01, Thursday 28 July 2016
H1 PEM (PEM, SEI)
david.mcmanus@LIGO.ORG - posted 11:01, Thursday 28 July 2016 - last comment - 18:10, Thursday 28 July 2016(28696)
NN array channel 7 I/O Chassis Problems

David.M, Filiberto.C

Yesterday I was looking at the NN array output channels to check everything was working and noticed that the 7th NN channel (H1:NGN-CS_L4C_Z_7_OUT) was producing a noisy output about 3 orders of magnitude higher than expected. I thought potentially the L4C might be busted, so I went into the LVEA this morning and swapped it out for another one that we tested earlier (L41429). The problem remained even with the new sensor and also even when the sensor was unplugged. We went into the CER to diagnose where the problem was. Turning off the L4C interface chassis and the AA chassis both didn't fix the problem, which seems to indicate that the large noise level in this channel is caused by a problem in the I/O Chassis.

Comments related to this report
david.mcmanus@LIGO.ORG - 18:10, Thursday 28 July 2016 (28716)

This problem was not fixed with an I/O chassis power cycle,  so it may be a problem with the ADC card.