stefan.ballmer@LIGO.ORG - posted 23:20, Sunday 31 July 2016 - last comment - 12:49, Monday 01 August 2016(28765)
LSC-PR_GAIN back at 30 for 50W

Terra, Evan, Stefan

With the spot move script from last alog we could reliably maximize the recycling gain. We reached 30 (as measured by LSC-PR_GAIN - Evan claims this is more like 35).

The instability in AS90 could be removed by manually aligning the SRM - but POP18 got worse when doing so.

Interestingly - the same move that fixes the recycling gain at 50W, has almost no impact on the recycling gain at 2W.

 

For reference, the last lock loss was at about 6:15 UTC on Aug 1st.

We had to adjust the soft loop gains to

            ezca['ASC-DSOFT_P_GAIN'] = 0.5 # 3 killed it
            ezca['ASC-DSOFT_Y_GAIN'] = 3  # oscillates at lower UGF when much lower
            ezca['ASC-CSOFT_P_GAIN'] = 0.5 # designed differently
            ezca['ASC-CSOFT_Y_GAIN'] = 3  # oscillates at lower UGF when much lower
 

Comments related to this report
stefan.ballmer@LIGO.ORG - 12:49, Monday 01 August 2016 (28777)

Estimating the spot mosition move required to regain the recycling gain.
====================================================

Conclusion: The corner spot moved by about 8mm in pitch and yaw.

The move direction (to improve the recycling gain) in each arm is a soft translation of the beam axis towards the other arm (yaw), as well as up (pit).
====================================================

 

We used two methods to estimate the spot move on the ITM/BS/PR3.

A) using IM4 angle readback:

Since PR2 doesn't move, looking at how much IM4 moved allows us top simply project the move on PR3. The effecive lever arm (incl. the PRM and PR2 lens effects) is 151.4m.

To regain the best recycling gain we moved IM4 26.2urad in pit and 25.5urad in yaw. This corresponds to (note the factor of 2 for beam steering vs optic angle)

IM4 PIT projection on PR3: 7.9337mm
IM4 YAW projection on PR3: 7.7217mm
 

B) using the test mass oplevs:

The move recorded by the test mass oplevs (in urad) are (EX,EY,IX,IY) are:

PIT:
    1.8700
    1.6500
    2.5000
    2.0600
YAW:
    2.7000
    2.8200
    3.3200
    3.2600

Since it is always hard to get a clean soft that is not masked by residual hard, we project out any spurios hard move.

i) Without removing the hard:
ITM:-1.9858mm, ETM:12.091mm
ITM:0.91049mm, ETM:7.2637mm
ITM:2.4191mm, ETM:10.6978mm
ITM:6.315mm, ETM:6.329mm
 

ii) removing the hard by forcing the ETM and ITM spot move to be the same:

i.e. we force the spot move to be the same on ETM and ITM:
ITM:4.5198mm, ETM:4.5198mm
ITM:3.8466mm, ETM:3.8466mm
ITM:6.2452mm, ETM:6.2452mm
ITM:6.3215mm, ETM:6.3215mm
 

iii) forcing the spot to be zero on the ETM (that's how we think we tuned the SOFT loop sensors):
ITM:8.4743mm, ETM:0mm
ITM:7.1944mm, ETM:0mm
ITM:11.674mm, ETM:0mm
ITM:11.7903mm, ETM:0mm

The reality probably lies between ii) and iii)

 

FInally, note that the control signal recorded in alog 28764 can't be used because of all the radiation pressure torque effects.

 