Measured 167.3W at the output of the high power oscillator. 162.5W at the input to the pre-modecleaner
with the ISS off.
The diffracted power versus offset slider position was measured. Combined with the power out of the
laser, this gave the percentage diffracted power. The free-running peak-to-peak power fluctuations
measured by the ISS photodiodes as reported by a trend of the PDB EPICS was 0.2Vpp with a mean value of
8.3V. So the 0.1Vp fluctuations represent ~1.2%.
Allowing for some margin, we wish to diffract 2%. 2% of 162.5W is 3.25W. With the digital support
loop on, this corresponds to an offset slider of ~2.5.
The polynomial fit calculating the percentage diffraction was: 220.159x**2 - 97.169x + 11.293.
This was changed to match the measurements done earlier to day to: 97.6751x**2 - 63.548x + 11.458. The
MEDM screen now correctly reports the amount of light diffracted by the ISS AOM.
Jason/Peter