Reports until 15:04, Tuesday 02 August 2016
H1 PSL (PSL)
peter.king@LIGO.ORG - posted 15:04, Tuesday 02 August 2016 - last comment - 15:48, Tuesday 02 August 2016(28813)
ISS changes
Measured 167.3W at the output of the high power oscillator.  162.5W at the input to the pre-modecleaner
with the ISS off.

    The diffracted power versus offset slider position was measured.  Combined with the power out of the
laser, this gave the percentage diffracted power.  The free-running peak-to-peak power fluctuations
measured by the ISS photodiodes as reported by a trend of the PDB EPICS was 0.2Vpp with a mean value of
8.3V.  So the 0.1Vp fluctuations represent ~1.2%.

    Allowing for some margin, we wish to diffract 2%.  2% of 162.5W is 3.25W.  With the digital support
loop on, this corresponds to an offset slider of ~2.5.

    The polynomial fit calculating the percentage diffraction was: 220.159x**2 - 97.169x + 11.293.
This was changed to match the measurements done earlier to day to: 97.6751x**2 - 63.548x + 11.458.  The
MEDM screen now correctly reports the amount of light diffracted by the ISS AOM.



Jason/Peter
Images attached to this report
Comments related to this report
peter.king@LIGO.ORG - 15:24, Tuesday 02 August 2016 (28815)
Recently the datasheet for the RF amplifier inside the AOM driver was looked at.
It suggested a continuous maximum RF input of 5dBm for absolutely no damage to one
of the chips used.  Thus a 5dB attenuator was added, bringing the total attenuation
to 6dB.
peter.king@LIGO.ORG - 15:48, Tuesday 02 August 2016 (28816)
Attached are plots of the ISS transfer function and the relative power noise for the corresponding
gain settings.

The spectra is of the out-of-loop photodiode.
Images attached to this comment