Another thing to add to the OMC inspection

A supplymental observation in addition to LHO ALOG 28820 was that we found (at least) one more epoxy delamination in the decomissioned OMC. The sympton is similar to the one found in the 3rd OMC last week ([LHO ALOG 28714])