STS and T240 centering checks. FAMIS task 6077 closed.
jim.warner@opsws0:scripts 0$ pwd
/opt/rtcds/userapps/trunk/isi/common/scripts
jim.warner@opsws0:scripts 0$ ./check_sts_centering.py h1
Averaging Mass Centering channels for 10 [sec] ...
2016-08-03 14:55:35.366977
All STSs prrof masses that within healthy range (< 2.0 [V]). Great!
Here's a list of how they're doing just in case you care:
STS A DOF X/U = -0.0 [V]
STS A DOF Y/V = -0.0 [V]
STS A DOF Z/W = -0.0 [V]
STS B DOF X/U = 0.14 [V]
STS B DOF Y/V = -1.259 [V]
STS B DOF Z/W = -0.163 [V]
STS C DOF X/U = -0.0 [V]
STS C DOF Y/V = -0.0 [V]
STS C DOF Z/W = -0.0 [V]
STS EX DOF X/U = -0.249 [V]
STS EX DOF Y/V = 0.603 [V]
STS EX DOF Z/W = 0.032 [V]
STS EY DOF X/U = 0.056 [V]
STS EY DOF Y/V = 0.369 [V]
STS EY DOF Z/W = 0.242 [V]
Assessment complete.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
jim.warner@opsws0:scripts 2$ ./check_T240_centering.py h1
Averaging Mass Centering channels for 10 [sec] ...
2016-08-03 14:54:50.368892
There are 1 T240 proof masses out of range ( > 0.3 [V] )!
ETMY T240 1 DOF Y/V = 0.392 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.065 [V]
ETMX T240 1 DOF Y/V = 0.062 [V]
ETMX T240 1 DOF Z/W = 0.08 [V]
ETMX T240 2 DOF X/U = -0.222 [V]
ETMX T240 2 DOF Y/V = -0.262 [V]
ETMX T240 2 DOF Z/W = -0.095 [V]
ETMX T240 3 DOF X/U = 0.035 [V]
ETMX T240 3 DOF Y/V = -0.023 [V]
ETMX T240 3 DOF Z/W = 0.048 [V]
ETMY T240 1 DOF X/U = 0.039 [V]
ETMY T240 1 DOF Z/W = 0.053 [V]
ETMY T240 2 DOF X/U = -0.085 [V]
ETMY T240 2 DOF Y/V = 0.056 [V]
ETMY T240 2 DOF Z/W = 0.055 [V]
ETMY T240 3 DOF X/U = 0.053 [V]
ETMY T240 3 DOF Y/V = 0.036 [V]
ETMY T240 3 DOF Z/W = 0.056 [V]
ITMX T240 1 DOF X/U = -0.16 [V]
ITMX T240 1 DOF Y/V = 0.175 [V]
ITMX T240 1 DOF Z/W = 0.121 [V]
ITMX T240 2 DOF X/U = 0.158 [V]
ITMX T240 2 DOF Y/V = 0.147 [V]
ITMX T240 2 DOF Z/W = 0.142 [V]
ITMX T240 3 DOF X/U = -0.089 [V]
ITMX T240 3 DOF Y/V = 0.108 [V]
ITMX T240 3 DOF Z/W = 0.167 [V]
ITMY T240 1 DOF X/U = 0.055 [V]
ITMY T240 1 DOF Y/V = -0.015 [V]
ITMY T240 1 DOF Z/W = -0.079 [V]
ITMY T240 2 DOF X/U = 0.102 [V]
ITMY T240 2 DOF Y/V = 0.094 [V]
ITMY T240 2 DOF Z/W = 0.047 [V]
ITMY T240 3 DOF X/U = -0.152 [V]
ITMY T240 3 DOF Y/V = 0.092 [V]
ITMY T240 3 DOF Z/W = -0.231 [V]
BS T240 1 DOF X/U = -0.053 [V]
BS T240 1 DOF Y/V = 0.028 [V]
BS T240 1 DOF Z/W = 0.096 [V]
BS T240 2 DOF X/U = 0.085 [V]
BS T240 2 DOF Y/V = 0.086 [V]
BS T240 2 DOF Z/W = 0.081 [V]
BS T240 3 DOF X/U = -0.08 [V]
BS T240 3 DOF Y/V = 0.037 [V]
BS T240 3 DOF Z/W = -0.062 [V]
Assessment complete.