Reports until 16:45, Wednesday 03 August 2016
H1 DAQ
jonathan.hanks@LIGO.ORG - posted 16:45, Wednesday 03 August 2016 (28855)
More on frame writer testing (splitting the producer thread)
As a follow up to (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=28749) we have a build of the framewriter on h1fw2 that splits the producer thread into two components.

Here is a sample timing:

producer thread timings
 recv min:0.0592079 mean:0.0624186 max:0.0642519
producer crc thread timings
 full min:0.0259149 mean:0.0270363 max:0.0351679
 crc  min:0.014359 mean:0.0144825 max:0.0150859
 xfer min:0.0115559 mean:0.0125535 max:0.0200801

The producer thread does nothing but receiving data.  Here we notice the time to receive is increased to the full 1/16s.  We believe this is largely a busy wait while it waits for the data to come in.