State of H1: OMC alignment work with IR beam started today, other parasitic work continues
Assistance: Stefan, Kiwamu, Sheila, JeffK
Alignment issue encountered and resolved:
Alignment of the IR beam to the OMC took a 200urad change in SR2 pitch, which Stefan and Kiwamu tracked down to a change on SR3 pitch driven by the cage servo, which read OSEM values.
The SR3 OSEMs had gotten some extra light and the servo moved the optic. Reseting SR3 restored the alignment to the OMC with only a reasonable (much less that 200urad) change on SR2.
OMC issue encountered and resolved:
Koji was unable to change the output of OMC-PZT2, which Sheila tracked down to a dependency on PZT1. Once the setting for PZT1 was changed, it was possible to manually control PZT2.
Activity: all times UTC
15:00-19:00:
-
kyle -ey - baking rga
-
joe - y arm - beam tube maintenance
-
ed - lvea - tracking down a cable
-
richard/ed - ecr -
-
fil/mark - ey - esd drive
-
travis - ex - pcal - laser hazard
-
krishna/michael - lvea vertex - seismometer
-
robert - ey - timing
-
betsy - ham6 - omc
-
tj - ham6 - omc
-
fil/mark - ex - esd drive
-
jimw - itmy - sei tests
-
nutsinee/jason - lvea - tcs hartman
-
jimw - ex - sei tests
-
daveb - ex, ey, lvea - sei labeling
-
fil/mark - ex - esd drive
everyone back for lunch ~19:00-20:00
20:00-23:00
-
koji - ham6 - omc
-
betsy - ham6 - omc
-
corey - ham6 - omc
-
fil/mark - ex - esd drive
-
jeffk - ex - charge
-
karen - ey - cleaning
-
nutsinee/jason - lvea - tcs hartman
-
mikel - lvea - tour
-
daveb - lvea - labeling sei
-
sudarshan/miranda - ey - pcal - laser hazard
-
kyle - ey - baking rga
-
fil/mark - ey - esd drive
-
robert - ey - timing
Currently: - people at these locations
-
robert - ey - timing
-
koji - lvea - ham6
-
betsy - lvea - ham6
-
corey - lvea - ham6
-
nutsinee - lvea - tcs
-
jason - lvea - tcs
-
krishna - lvea - seismometer/vertex
-
fil - ex - esd drive
-
mikel - lvea - tour
Currently: - issues with H1
-
ey front end is down, went down at 22:00utc - daveb working on it
Log for last half hour of the day:
22:35 Dave restarting EY SUS front end
22:40 I reset ETMy, TMSy, and EY ISI watchdogs
22:43 TJ to HAM 6 to deliver CDS laptop
22:47 Jason and Nutsinee out of LVEA