State of alignment: restored and beam is in HAM6
Assistance: JeffK, Jenne
Activities:
-
All front ends restarted today, recovery of input optics included the PZTs and IMs.
-
I also chose to align the IMC optics, MC1, MC2, MC3, back to thei locked values at 15:00UTC today (8/9), which is actually doing a WFS reflief.
-
ALL MC optics will show a change in alignment slider values - this is expected.
-
After restoring PZTs, IMC locked quickly, and has been stable since.
-
IMs are restored to values in alog 28016.
-
JeffK restored all optics downstream of IMs.
-
Beam from the PSL is slightly different than yesterday (within the normal variance), and ITMY is 0.5urad different in yaw - talked to crew at HAM6 so they're aware.
-
Once the PSL beam was making it to the OMC, OM1, OM2, and OM3 were moving a lot - tracked down to an chassis being turned off, now restored.
-
OM1-3 needed some alignment - values are from 15:00UTC yesterday, when work ended - image is attached.
-
SR2's alignment is a bit different than yesterday's by 7urad pitch and 14urad yaw - alignment yesterday 2553.7 pitch, 744.9 yaw - texted to Corey if they need to set it back.
-