chandra.romel@LIGO.ORG - posted 10:38, Thursday 11 August 2016 - last comment - 10:45, Thursday 11 August 2016(29019)
GV5 & 7 OPEN
Arm GV 5 & 7 are now open. Closed WPs 6030 and 6075.
Cracked the gate annulus valve to let AIP pump any outgassing build up in that space. GV7's AIP showed no change. GV5's AIP rose to 5 mA and then settled back down to 1 mA after a few seconds.
Comments related to this report
kyle.ryan@LIGO.ORG - 10:45, Thursday 11 August 2016 (29020)
Is the interpretation of the differing responses to the "burping" of the gate annulus volumes into the adjacent annulus volumes that GV5's gate was in full contact with its sealing surface, and therefore hasn't been pumped since being soft-closed while GV7's gate was not in full contact and has thus been pumped by the XBM volume since being soft-closed?