Displaying report 1-1 of 1.
Reports until 15:13, Thursday 11 August 2016
H1 ISC
terra.hardwick@LIGO.ORG - posted 15:13, Thursday 11 August 2016 (29028)
SUS_PI, ISC_LOCK guardian edited for ETM ESD mod

Recent mods to the ETM ESDs (alog 28939) allow PI signals to drive even while ETM ESD is in the HV mode. I've edited the SUS_PI and ISC_LOCK guardians to account for this. Both reloaded successfully.

Previously the PI damping path for ETMs required the ESD be in LV mode == not be in HV mode. Because of this, we could not damp PI on ETMX until the ISC_LOCK state LOWNOISE_ESD_ETMY (as prior to this we are actively using ETMX ESD in HV mode for lock aquisition). PI damping for the 3 other test masses was turned on during DC_READOUT. ECR E1600230 now allows PI drive even when the LV driver is in HV mode. Now all damping turns on during DC_READOUT. 

Displaying report 1-1 of 1.