J. Kissel
I took an opportunity between shutter testing and beckhoff problems to gather the final at-vacuum measurements of the HAM6 SUS. I'll process the data in complete detail tomorrow (I attach a screenshot of an example DOF from the OMC), but the message is that the TFs look just as good as they did before the vent: free, clear of rubbing, and all resonances are at the same frequency with roughly the same Q.
Excellent!
Watch this space for full analysis and comparison with previous results.
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data/
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_L_0p02to50Hz.xml
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_P_0p02to50Hz.xml
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_R_0p02to50Hz.xml
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_T_0p02to50Hz.xml
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_V_0p02to50Hz.xml
2016-08-11_2305_H1SUSOMC_M1_WhiteNoise_Y_0p02to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM1/SAGM1/Data/
2016-08-11_2249_H1SUSOM1_M1_WhiteNoise_L_0p03to50Hz.xml
2016-08-11_2249_H1SUSOM1_M1_WhiteNoise_P_0p03to50Hz.xml
2016-08-11_2249_H1SUSOM1_M1_WhiteNoise_Y_0p03to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM2/SAGM1/Data/
2016-08-11_2151_H1SUSOM2_M1_WhiteNoise_L_0p03to50Hz.xml
2016-08-11_2151_H1SUSOM2_M1_WhiteNoise_P_0p03to50Hz.xml
2016-08-11_2151_H1SUSOM2_M1_WhiteNoise_Y_0p03to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM3/SAGM1/Data/
2016-08-11_2257_H1SUSOM3_M1_WhiteNoise_L_0p03to50Hz.xml
2016-08-11_2257_H1SUSOM3_M1_WhiteNoise_P_0p03to50Hz.xml
2016-08-11_2257_H1SUSOM3_M1_WhiteNoise_Y_0p03to50Hz.xml