stefan.ballmer@LIGO.ORG - posted 18:23, Thursday 11 August 2016 - last comment - 21:11, Thursday 11 August 2016(29036)
Fast shutter no longer bouncing open again

We triggered the fst shutter a couple of times by lowering the threshold (i.e. ensuring that the alanog electronics fires the shutter), and wee verified that we didn't see any bounce after 60ms to 100ms (as loged before in alog 28958 ).

Attached are plots for one trigger, on different time scales.

Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 21:08, Thursday 11 August 2016 (29040)

Here's a 2nd fast shutter test. Again, no bounce.

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:10, Thursday 11 August 2016 (29041)

And another one.

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:11, Thursday 11 August 2016 (29042)

And another one.

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:11, Thursday 11 August 2016 (29043)

ANd a last one.