Over-filled CP3 at 21:30 utc

Over-filled CP3 with the exhaust bypass valve fully open and the LLCV bypass valve 1/2 turn open.

Flow was noted after 10 minutes 23 seconds, closed LLCV valve, and 3 minutes later the exhaust bypass valve was closed.

Comments related to this report
gerardo.moreno@LIGO.ORG - 15:20, Friday 12 August 2016 (29070)
I raised CP3's LLCV from 18% to 19%, due to the amount of time it took to overfill today.