OMC alignment turned off

The OMC alignment servos keep turning on, even though the OMC guardian is paused.  I found that it gets turned on in engage_wfs_centering whenever we do any ASC since it's in a generate states function.  So, I have commented out that line, but we must uncomment it when we have the OMC back and are ready to use it again.  It is currently line 113 in ISC_GEN_STATES.

Comments related to this report
hugh.radkins@LIGO.ORG - 08:47, Monday 01 August 2016 (28768)

Maybe this should have a work permit to make sure this isn't forgotten; or at least some mechanism to undo the change in a timely manner.

corey.gray@LIGO.ORG - 08:07, Wednesday 17 August 2016 (29145)

Not sure when it happened, but looks like this has been restored to normal & uncommented (probably some time after the HAM6 work last week).