Reports until 16:23, Tuesday 22 May 2012
corey.gray@LIGO.ORG -
posted 16:23, Tuesday 22 May 2012 (2916)
BSC6 Activities
-
Keita spent first part of morning investigating TMS mis-alignment (Hugh confirmed it was NOT ISI/HEPI-related).
-
VEA was then transitioned to LASER SAFE after his work.
-
Doug/Jason continued alignment work in the afternoon
Misc
-
Dave rebooted h2DAQ just after 8am
-
CP1 was filled via Praxair
-
EY Dust Monitor alarmed for one cycle (100-200 counts). After this alarm,noticed a "red box" around this dust monitor on the medm screen. The box was red because there is a "calibrate failure". Patrick said that if the status doesn't change, this dust monitor will need to be swapped out.