Reports until 15:56, Friday 19 August 2016
LHO VE
chandra.romel@LIGO.ORG - posted 15:56, Friday 19 August 2016 - last comment - 17:11, Friday 19 August 2016(29206)
HAM 6 turbo spun down
Kyle, Chandra

Isolated turbo on top of HAM 6 and spun it down, turned off scroll pump, decoupled foreline piping. Left turbo energized until bearing if fully de-levitated. 

NOTE: climbed on top of HAM 6 to do this work. 

Will de-energize turbo by Monday.
Images attached to this report
Comments related to this report
kyle.ryan@LIGO.ORG - 17:11, Friday 19 August 2016 (29210)
I had intended to shut down the pump cart pumping the Vertex RGA (also de-energize the HAM6 turbo controller) on Saturday morning, decouple it and then combine (valve-in) the RGA to the Vertex volume.  However, I forgot to get a Work Permit approved for this prior to people exiting for the weekend.  I confirmed with Keita, Sheila and Terra that their activities would not be hindered by leaving this noise source running over the weekend so, I will do this on Monday morning.