Reports until 10:39, Tuesday 23 August 2016
H1 CDS
david.barker@LIGO.ORG - posted 10:39, Tuesday 23 August 2016 (29245)
new sus etm code, bad DAQ restart

Darkham, Jeff, Jim, Dave:

h1susetm[x,y] models were restarted following changes to QUAD_MASTER.mdl.

Change is to replace DAQ DQ channel H1:SUS-ETMY_LKIN_P_LO_DQ with H1:SUS-ETMY_L3_CAL2_LINE_OUT_DQ and add an oscillator (H1:SUS-ETMY_L3_CAL2_LINE).

DAQ did not restart nicely. My change to add h1sysecatxxplcysdf INI and PAR files to daq master caused h1dc0 to stop on error "channel '' has bad DCU id 1024". I have removed these from the master and the DAQ is running.