Reports until 18:36, Wednesday 24 August 2016
H1 CAL (CAL)
darkhan.tuyenbayev@LIGO.ORG - posted 18:36, Wednesday 24 August 2016 (29291)
Calibration line status

Jeff K, Darkhan T,

Last Tuesday we updated the infrastructure for injecting calibration lines (see LHO alogs 29245, 29249). Below is the table of currently active calibration lines:

Channel Names                 _FREQ (Hz)  _SINGAIN (ct)
H1:CAL-PCALY_PCALOSC1_OSC        36.7            125       O1-scheme kappa_TST / kappa_PU
H1:CAL-PCALY_PCALOSC2_OSC       331.9           2900       O1-scheme kappa_C / f_C


H1:CAL-PCALY_PCALOSC3_OSC      1083.7          15000       high-frequency calibration check ("bonus" line)

H1:CAL-PCALX_PCALOSC1_OSC      3501.3          39322       high-frequency sensing function characterization ("mobile" line)

                              _FREQ (Hz)  _CLKGAIN (ct)
H1:CAL-CS_TDEP_DARM_LINE1_DEMOD  37.3              0.1     O1-scheme kappa_PU
H1:SUS-ETMY_L3_CAL_LINE          35.9              0.11    O1-scheme kappa_TST / kappa_PU


H1:SUS-ETMY_L1_CAL_LINE          33.7             11       O2-scheme synched oscillator for kappa_U
H1:SUS-ETMY_L2_CAL_LINE          34.7              1.1     O2-scheme synched oscillator for kappa_P
H1:SUS-ETMY_L3_CAL2_LINE         35.3              0.11    O2-scheme synched oscillator for kappa_T

We plan to adjust the three O2-scheme line frequencies and amplitudes, and cancel them out with PCALY (they will not appear in the reconstructed DARM spectrum), following synchronized oscillators will be utilized for this purpose H1:CAL-PCALY_PCALOSC{4-6}_OSC.