We had a couple locklosses when the ISS saturated, both with the third loop on and off. We just increased the ref signal to -1.52 V to move the diffracted power to around 4%. Was some setting incorect after a reboot this morning? SDF indicated that everythind is OK.
Note that the H1:PSL-ISS_CTRL_OFFSET used to be 2.5, but yesterday Keita and I changed it to 3.85. Thank you Jason & Jeff for pointing out that I forgot to write an alog.
We made this adjustment with the ISS first loop off, and set the offset such that the diffracted power was a little over 3%. Before doing this, the diffracted power was 1.7% with the first loop off, and we kept hitting the bottom rail, which would send the first loop into oscillation and cause it to unlock. We were able to close the 1st loop, and everything looked okay. So, 3.85 is the new best value.
With all that said, we've had a few times over the last 3 days of hitting the bottom rail of the ISS when we've got the IFO locked, and it changes the power injected into the vacuum and the IFO oscillates a bit although usually retains lock. We may need to consider increasing the first loop offset even more, so that we're a teeny bit farther away from that rail.